Auszug der Referenzliste

Scope Client Flue gas flow rate [m³/h] SOx inlet
SOx outlet
[mg/Nm³]
HCI inlet
HCI outlet
[mg/Nm³]
Dust inlet
Dust outlet
[mg/Nm³]
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers EC LUBIN, Poland 2 x 194.000 1.500 / 1.125
150
200
300
100 – 1.000
5
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers EC Skierniewice, Poland 1 x 189.000 & 1 x 179.000 2.000 / 950
200
280
5
100 – 1.000
10
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers EC-2 Polkowice, Poland 2 x 240.000 1.500 / 1.125
150
65
3
100 – 1.000
5
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers MPEC Wloclawek, Poland 1 x 188.000 & 1 x 90.000 2.500 / 1.125
200
350
10
100 – 1.000
10
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers RADPEC RADOM Poludnie, Poland 1 x 85.000 & 1 x 157.500 2.700
160
175
4
< 400
10
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers RADPEC RADOM Polnoc, Poland 2 x 85.000 & 1 x 170.000 2.700
160
175
4
< 400