Dry-Flue Gas Desulphurization
Auszug der Referenzliste
Scope | Client | Flue gas flow rate [m³/h] | SOx inlet SOx outlet [mg/Nm³] |
HCI inlet HCI outlet [mg/Nm³] |
Dust inlet Dust outlet [mg/Nm³] |
---|---|---|---|---|---|
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers | EC LUBIN, Poland | 2 x 194.000 | 1.500 / 1.125 150 |
200 300 |
100 – 1.000 5 |
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers | EC Skierniewice, Poland | 1 x 189.000 & 1 x 179.000 | 2.000 / 950 200 |
280 5 |
100 – 1.000 10 |
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers | EC-2 Polkowice, Poland | 2 x 240.000 | 1.500 / 1.125 150 |
65 3 |
100 – 1.000 5 |
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers | MPEC Wloclawek, Poland | 1 x 188.000 & 1 x 90.000 | 2.500 / 1.125 200 |
350 10 |
100 – 1.000 10 |
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers | RADPEC RADOM Poludnie, Poland | 1 x 85.000 & 1 x 157.500 | 2.700 160 |
175 4 |
< 400 10 |
Engineering, component supply and commissioning of CFB-S-Reactor & Fabric Filter downstream lignite fired boilers | RADPEC RADOM Polnoc, Poland | 2 x 85.000 & 1 x 170.000 | 2.700 160 |
175 4 |
< 400 10 |