Yara Trinidad
Waste Heat Boiler downstream secondary reformer in an ammonia plant

Legende
Ausgewählte Referenzen von Steinmüller Engineering
Erfolge
- Replacement of existing waste heat boiler with design improvements (Bayonette-type replaced by U-Tube heating surface)
- Application: WHB downstream secondary reformer in TRINGEN 1 ammonia plant
- Vertical water tube boiler, forced circulation 200 t/h, 103 bar, 319 °C, 208 t/h syngas cooled down from 980°C to 470°C @ 32bar
- Engineering and supply in 2014
Umfang des Angebots
- Basic and detail design of waste heat boiler
- Process design, including CFD optimization
- Manufacturing of boiler, consisting of U-Tube bundle incl. water and steam chamber
- Pressure vessel
- Double layer refractory lining

Ansprechpartner
Torsten Klose
Sales Director Southwest Europe & MENA
Telefon +49 2261 78950 538
Mobil +49 160 3696 096
Schreiben Sie eine E-Mail