Yara Trinidad

Waste Heat Boiler downstream secondary reformer in an ammonia plant

Legende Ausgewählte Referenzen von Steinmüller Engineering

Erfolge

  • Replacement of existing waste heat boiler with design improvements (Bayonette-type replaced by U-Tube heating surface)
  • Application: WHB downstream secondary reformer in TRINGEN 1 ammonia plant
  • Vertical water tube boiler, forced circulation 200 t/h, 103 bar, 319 °C, 208 t/h syngas cooled down from 980°C to 470°C @ 32bar
  • Engineering and supply in 2014

Umfang des Angebots

  • Basic and detail design of waste heat boiler
  • Process design, including CFD optimization
  • Manufacturing of boiler, consisting of U-Tube bundle incl. water and steam chamber
  • Pressure vessel
  • Double layer refractory lining

Ansprechpartner

Torsten Klose

Sales Director Southwest Europe & MENA
Telefon +49 2261 78950 538
Mobil +49 160 3696 096
Schreiben Sie eine E-Mail

Sie haben ein Projekt?

 

> Kontaktieren Sie uns.

 

STAMMSITZ

Steinmüller Engineering GmbH
IHI Group Company
Fabrikstraße 5
51643 Gummersbach / Germany

Logo: IHI Corporation

 

 

 

Logo: DimBo