Solvay/Butachimie Chlampé
Waste Heat Boiler for Catalytic HCN Synthesis in a Nylon Plant > Steam Generation Technology

Legend
Selected References of Steinmüller Engineering
Achievements
- Replacement of waste heat boiler with improved design features
- Capacity increase of boiler by 15%
- Improved cooling of critical components
Boiler design:
- Application: catalytic HCN synthesis, steam generation and cooling of hot process gases (> 1100°C)
- Vertical fire-tube boiler with natural circulation, 121 t/h, 26,5 bar, 227°C
- Conical design of tube sheet for improved steam discharge
- Engineering and supply by Steinmüller Engineering in 2013
Scope of Supply
- Design of new waste heat bpiler for the existing plant
- Process engineering
- Mechanical design (basic and detail)
- Manufacturing and supply of boiler
- Transport to site
- Supply and installation of refractory